{"id":19973,"date":"2025-03-26T08:54:40","date_gmt":"2025-03-26T08:54:40","guid":{"rendered":"https:\/\/hvr-magnet.com\/?p=19973"},"modified":"2025-06-04T08:46:36","modified_gmt":"2025-06-04T08:46:36","slug":"why-injection-mold-drops-with-magnetic-platens","status":"publish","type":"post","link":"https:\/\/hvr-magnet.com\/fr\/why-injection-mold-drops-with-magnetic-platens\/","title":{"rendered":"Pourquoi des moules \u00e0 injection avec des plateaux magn\u00e9tiques ?"},"content":{"rendered":"<p><a href=\"https:\/\/hvr-magnet.com\/fr\/magnetic-quick-mold-change-system\/\">Plateaux magn\u00e9tiques<\/a> Les syst\u00e8mes de serrage sont devenus indispensables aux proc\u00e9d\u00e9s modernes de moulage par injection, offrant des avantages significatifs par rapport aux syst\u00e8mes de serrage traditionnels en termes de rapidit\u00e9 et de facilit\u00e9 de changement de moule. Cependant, comme pour tout syst\u00e8me m\u00e9canique, des probl\u00e8mes peuvent survenir, conduisant au sc\u00e9nario redout\u00e9 de la chute du moule. Cet article explore les conditions dans lesquelles un plateau magn\u00e9tique peut faire chuter un moule. Il met en \u00e9vidence les causes courantes et propose des solutions pour \u00e9viter de tels incidents.<\/p>\n<h3><strong>Fonctionnement et configuration incorrects<\/strong><\/h3>\n<p>L&#039;une des causes les plus fr\u00e9quentes de chutes de moules est une mauvaise utilisation et une mauvaise configuration de la part de l&#039;op\u00e9rateur charg\u00e9 du changement de moules. Parmi ces causes figurent\u00a0:<\/p>\n<p>Dimensionnement incorrect du moule\u00a0: Si le moule \u00e0 changer ne respecte pas les sp\u00e9cifications du plateau magn\u00e9tique, cela peut entra\u00eener une instabilit\u00e9 lors du serrage, pouvant entra\u00eener une chute. Il est crucial de s&#039;assurer que les dimensions du moule respectent les param\u00e8tres sp\u00e9cifi\u00e9s du plateau magn\u00e9tique.<\/p>\n<p>Mauvais r\u00e9glages d&#039;usinage\u00a0: Des probl\u00e8mes de r\u00e9glage de la machine ou des r\u00e9glages incorrects lors du changement de moule peuvent compromettre la force de serrage et entra\u00eener un d\u00e9moulage inattendu. Une formation ad\u00e9quate et le respect des protocoles d&#039;utilisation de la machine sont essentiels.<img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-19975 aligncenter\" src=\"https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/electro-permanent-magnetic-mold-clamping-system-1000x563.jpg\" alt=\"electro permanent magnetic mold clamping system\" width=\"1000\" height=\"563\" srcset=\"https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/electro-permanent-magnetic-mold-clamping-system-1000x563.jpg 1000w, https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/electro-permanent-magnetic-mold-clamping-system-768x432.jpg 768w, https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/electro-permanent-magnetic-mold-clamping-system-1536x864.jpg 1536w, https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/electro-permanent-magnetic-mold-clamping-system.jpg 1920w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<h3><strong>Mauvaise qualit\u00e9 des plateaux magn\u00e9tiques et tests insuffisants<\/strong><\/h3>\n<p>La qualit\u00e9 du plateau magn\u00e9tique lui-m\u00eame, ainsi que l&#039;absence de tests approfondis, peuvent \u00e9galement entra\u00eener des chutes de moisissures. Parmi ces facteurs figurent\u00a0:<\/p>\n<p>Mat\u00e9riau du plateau de qualit\u00e9 inf\u00e9rieure : si le plateau magn\u00e9tique est fabriqu\u00e9 \u00e0 partir de mat\u00e9riaux de mauvaise qualit\u00e9, il risque de ne pas r\u00e9sister aux rigueurs des changements de moule r\u00e9p\u00e9t\u00e9s ou \u00e0 la contrainte de maintenir une force de serrage serr\u00e9e au fil du temps.<\/p>\n<p>Tests et surveillance limit\u00e9s\u00a0: Un plateau magn\u00e9tique aux capacit\u00e9s de diagnostic limit\u00e9es, voire inexistantes, ne peut alerter les op\u00e9rateurs des probl\u00e8mes potentiels avant qu&#039;ils ne surviennent. Des syst\u00e8mes de surveillance continue et des tests r\u00e9guliers des performances magn\u00e9tiques et des capacit\u00e9s de serrage constituent des mesures pr\u00e9ventives essentielles.<\/p>\n<h3><strong>Solutions et recommandations pour l&#039;utilisation de plateaux magn\u00e9tiques<\/strong><\/h3>\n<p>Pour \u00e9viter les chutes de moisissures li\u00e9es aux plateaux magn\u00e9tiques, envisagez les solutions suivantes\u00a0:<\/p>\n<ol>\n<li>Formation des op\u00e9rateurs : Assurez-vous que tous les op\u00e9rateurs de changement de moule sont correctement form\u00e9s \u00e0 l&#039;utilisation correcte du syst\u00e8me de plateau magn\u00e9tique, y compris \u00e0 la mani\u00e8re de mesurer et de positionner avec pr\u00e9cision les moules dans les dimensions sp\u00e9cifi\u00e9es.<\/li>\n<li>Proc\u00e9dures op\u00e9rationnelles standard (SOP) : \u00c9laborer et appliquer des SOP pour les op\u00e9rations de changement de moule, y compris la configuration des machines et les protocoles de s\u00e9curit\u00e9.<\/li>\n<li>Assurance qualit\u00e9 : utilisez des plateaux magn\u00e9tiques de haute qualit\u00e9 et effectuez des inspections r\u00e9guli\u00e8res pour confirmer que les mat\u00e9riaux et la construction sont adapt\u00e9s aux exigences de votre application.<\/li>\n<li>Tests et surveillance complets\u00a0: \u00e9quipez vos plateaux magn\u00e9tiques de syst\u00e8mes de test complets. Surveillez-les r\u00e9guli\u00e8rement pour d\u00e9tecter tout probl\u00e8me d&#039;intensit\u00e9 du champ magn\u00e9tique ou de performance de serrage. Si possible, mettez en place des syst\u00e8mes automatis\u00e9s pour alerter les op\u00e9rateurs des probl\u00e8mes potentiels.<\/li>\n<li>Entretien r\u00e9gulier : planifiez un entretien r\u00e9gulier de votre syst\u00e8me de plateau magn\u00e9tique pour rem\u00e9dier \u00e0 toute usure ou d\u00e9gradation des composants qui pourrait compromettre ses performances.<img decoding=\"async\" class=\"size-medium wp-image-19976 aligncenter\" src=\"https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/mold-clamping-magnetic-platen-1000x563.jpg\" alt=\"mold clamping magnetic platen\" width=\"1000\" height=\"563\" srcset=\"https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/mold-clamping-magnetic-platen-1000x563.jpg 1000w, https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/mold-clamping-magnetic-platen-768x432.jpg 768w, https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/mold-clamping-magnetic-platen-1536x864.jpg 1536w, https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/mold-clamping-magnetic-platen.jpg 1920w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/li>\n<\/ol>\n<h3><strong>Conclusion<\/strong><\/h3>\n<p>Comprendre et traiter les causes des chutes de moule gr\u00e2ce aux plateaux magn\u00e9tiques permet aux fabricants de b\u00e9n\u00e9ficier de cycles de production plus rapides et d&#039;une efficacit\u00e9 accrue, sans compromettre la s\u00e9curit\u00e9 et la fiabilit\u00e9.<\/p>","protected":false},"excerpt":{"rendered":"<p>Les plateaux magn\u00e9tiques sont devenus indispensables aux proc\u00e9d\u00e9s modernes de moulage par injection, offrant des avantages significatifs par rapport aux syst\u00e8mes de serrage traditionnels en termes de rapidit\u00e9 et de facilit\u00e9 de changement de moule. Cependant, comme pour tout syst\u00e8me m\u00e9canique, des probl\u00e8mes peuvent survenir, conduisant au sc\u00e9nario redout\u00e9 de la chute du moule. Cet article explore [\u2026]<\/p>","protected":false},"author":1,"featured_media":19974,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[30],"tags":[],"class_list":["post-19973","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-quick-mold-change"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Mold Drops - Reasons You Must Consider About Magnetic Platens<\/title>\n<meta name=\"description\" content=\"How magnetic platens drop a mold? This article highlights common causes and offering solutions to prevent such occurrences.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/hvr-magnet.com\/fr\/why-injection-mold-drops-with-magnetic-platens\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Mold Drops - Reasons You Must Consider About Magnetic Platens\" \/>\n<meta property=\"og:description\" content=\"How magnetic platens drop a mold? This article highlights common causes and offering solutions to prevent such occurrences.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/hvr-magnet.com\/fr\/why-injection-mold-drops-with-magnetic-platens\/\" \/>\n<meta property=\"og:site_name\" content=\"HVRMAG\" \/>\n<meta property=\"article:published_time\" content=\"2025-03-26T08:54:40+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-04T08:46:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/magnetic-platens.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"hvrma\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"hvrma\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/why-injection-mold-drops-with-magnetic-platens\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/why-injection-mold-drops-with-magnetic-platens\\\/\"},\"author\":{\"name\":\"hvrma\",\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/#\\\/schema\\\/person\\\/bca22fe3cd7a7b031e788829ffdefd3e\"},\"headline\":\"Why Injection Mold Drops with Magnetic Platens?\",\"datePublished\":\"2025-03-26T08:54:40+00:00\",\"dateModified\":\"2025-06-04T08:46:36+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/why-injection-mold-drops-with-magnetic-platens\\\/\"},\"wordCount\":471,\"publisher\":{\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/why-injection-mold-drops-with-magnetic-platens\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/hvr-magnet.com\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/magnetic-platens.jpg\",\"articleSection\":[\"Quick Mold Change\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/why-injection-mold-drops-with-magnetic-platens\\\/\",\"url\":\"https:\\\/\\\/hvr-magnet.com\\\/why-injection-mold-drops-with-magnetic-platens\\\/\",\"name\":\"Mold Drops - Reasons You Must Consider About Magnetic Platens\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/why-injection-mold-drops-with-magnetic-platens\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/why-injection-mold-drops-with-magnetic-platens\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/hvr-magnet.com\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/magnetic-platens.jpg\",\"datePublished\":\"2025-03-26T08:54:40+00:00\",\"dateModified\":\"2025-06-04T08:46:36+00:00\",\"description\":\"How magnetic platens drop a mold? This article highlights common causes and offering solutions to prevent such occurrences.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/why-injection-mold-drops-with-magnetic-platens\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/hvr-magnet.com\\\/why-injection-mold-drops-with-magnetic-platens\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/why-injection-mold-drops-with-magnetic-platens\\\/#primaryimage\",\"url\":\"https:\\\/\\\/hvr-magnet.com\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/magnetic-platens.jpg\",\"contentUrl\":\"https:\\\/\\\/hvr-magnet.com\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/magnetic-platens.jpg\",\"width\":1920,\"height\":1080,\"caption\":\"magnetic platens\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/why-injection-mold-drops-with-magnetic-platens\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/hvr-magnet.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Why Injection Mold Drops with Magnetic Platens?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/#website\",\"url\":\"https:\\\/\\\/hvr-magnet.com\\\/\",\"name\":\"HVRMAG\",\"description\":\"Magnetic Solution for Steel Handling\",\"publisher\":{\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/hvr-magnet.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/#organization\",\"name\":\"HVRMAG\",\"url\":\"https:\\\/\\\/hvr-magnet.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/hvr-magnet.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/23-4.png\",\"contentUrl\":\"https:\\\/\\\/hvr-magnet.com\\\/wp-content\\\/uploads\\\/2025\\\/08\\\/23-4.png\",\"width\":180,\"height\":60,\"caption\":\"HVRMAG\"},\"image\":{\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/hvr-magnet.com\\\/#\\\/schema\\\/person\\\/bca22fe3cd7a7b031e788829ffdefd3e\",\"name\":\"hvrma\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c79bd392ad38f9dd3d4ea71faed6976fdf273569bdcc3e829039ed7533c4225e?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c79bd392ad38f9dd3d4ea71faed6976fdf273569bdcc3e829039ed7533c4225e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c79bd392ad38f9dd3d4ea71faed6976fdf273569bdcc3e829039ed7533c4225e?s=96&d=mm&r=g\",\"caption\":\"hvrma\"},\"url\":\"https:\\\/\\\/hvr-magnet.com\\\/fr\\\/author\\\/dp_admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Mold Drops - Reasons You Must Consider About Magnetic Platens","description":"How magnetic platens drop a mold? This article highlights common causes and offering solutions to prevent such occurrences.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/hvr-magnet.com\/fr\/why-injection-mold-drops-with-magnetic-platens\/","og_locale":"fr_FR","og_type":"article","og_title":"Mold Drops - Reasons You Must Consider About Magnetic Platens","og_description":"How magnetic platens drop a mold? This article highlights common causes and offering solutions to prevent such occurrences.","og_url":"https:\/\/hvr-magnet.com\/fr\/why-injection-mold-drops-with-magnetic-platens\/","og_site_name":"HVRMAG","article_published_time":"2025-03-26T08:54:40+00:00","article_modified_time":"2025-06-04T08:46:36+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/magnetic-platens.jpg","type":"image\/jpeg"}],"author":"hvrma","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"hvrma","Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/hvr-magnet.com\/why-injection-mold-drops-with-magnetic-platens\/#article","isPartOf":{"@id":"https:\/\/hvr-magnet.com\/why-injection-mold-drops-with-magnetic-platens\/"},"author":{"name":"hvrma","@id":"https:\/\/hvr-magnet.com\/#\/schema\/person\/bca22fe3cd7a7b031e788829ffdefd3e"},"headline":"Why Injection Mold Drops with Magnetic Platens?","datePublished":"2025-03-26T08:54:40+00:00","dateModified":"2025-06-04T08:46:36+00:00","mainEntityOfPage":{"@id":"https:\/\/hvr-magnet.com\/why-injection-mold-drops-with-magnetic-platens\/"},"wordCount":471,"publisher":{"@id":"https:\/\/hvr-magnet.com\/#organization"},"image":{"@id":"https:\/\/hvr-magnet.com\/why-injection-mold-drops-with-magnetic-platens\/#primaryimage"},"thumbnailUrl":"https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/magnetic-platens.jpg","articleSection":["Quick Mold Change"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/hvr-magnet.com\/why-injection-mold-drops-with-magnetic-platens\/","url":"https:\/\/hvr-magnet.com\/why-injection-mold-drops-with-magnetic-platens\/","name":"Mold Drops - Reasons You Must Consider About Magnetic Platens","isPartOf":{"@id":"https:\/\/hvr-magnet.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/hvr-magnet.com\/why-injection-mold-drops-with-magnetic-platens\/#primaryimage"},"image":{"@id":"https:\/\/hvr-magnet.com\/why-injection-mold-drops-with-magnetic-platens\/#primaryimage"},"thumbnailUrl":"https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/magnetic-platens.jpg","datePublished":"2025-03-26T08:54:40+00:00","dateModified":"2025-06-04T08:46:36+00:00","description":"How magnetic platens drop a mold? This article highlights common causes and offering solutions to prevent such occurrences.","breadcrumb":{"@id":"https:\/\/hvr-magnet.com\/why-injection-mold-drops-with-magnetic-platens\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/hvr-magnet.com\/why-injection-mold-drops-with-magnetic-platens\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/hvr-magnet.com\/why-injection-mold-drops-with-magnetic-platens\/#primaryimage","url":"https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/magnetic-platens.jpg","contentUrl":"https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/03\/magnetic-platens.jpg","width":1920,"height":1080,"caption":"magnetic platens"},{"@type":"BreadcrumbList","@id":"https:\/\/hvr-magnet.com\/why-injection-mold-drops-with-magnetic-platens\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/hvr-magnet.com\/"},{"@type":"ListItem","position":2,"name":"Why Injection Mold Drops with Magnetic Platens?"}]},{"@type":"WebSite","@id":"https:\/\/hvr-magnet.com\/#website","url":"https:\/\/hvr-magnet.com\/","name":"HVRMAG","description":"Solution magn\u00e9tique pour la manutention de l&#039;acier","publisher":{"@id":"https:\/\/hvr-magnet.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/hvr-magnet.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/hvr-magnet.com\/#organization","name":"HVRMAG","url":"https:\/\/hvr-magnet.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/hvr-magnet.com\/#\/schema\/logo\/image\/","url":"https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/08\/23-4.png","contentUrl":"https:\/\/hvr-magnet.com\/wp-content\/uploads\/2025\/08\/23-4.png","width":180,"height":60,"caption":"HVRMAG"},"image":{"@id":"https:\/\/hvr-magnet.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/hvr-magnet.com\/#\/schema\/person\/bca22fe3cd7a7b031e788829ffdefd3e","name":"hvrma","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/c79bd392ad38f9dd3d4ea71faed6976fdf273569bdcc3e829039ed7533c4225e?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c79bd392ad38f9dd3d4ea71faed6976fdf273569bdcc3e829039ed7533c4225e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c79bd392ad38f9dd3d4ea71faed6976fdf273569bdcc3e829039ed7533c4225e?s=96&d=mm&r=g","caption":"hvrma"},"url":"https:\/\/hvr-magnet.com\/fr\/author\/dp_admin\/"}]}},"_links":{"self":[{"href":"https:\/\/hvr-magnet.com\/fr\/wp-json\/wp\/v2\/posts\/19973","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hvr-magnet.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hvr-magnet.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hvr-magnet.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/hvr-magnet.com\/fr\/wp-json\/wp\/v2\/comments?post=19973"}],"version-history":[{"count":2,"href":"https:\/\/hvr-magnet.com\/fr\/wp-json\/wp\/v2\/posts\/19973\/revisions"}],"predecessor-version":[{"id":20207,"href":"https:\/\/hvr-magnet.com\/fr\/wp-json\/wp\/v2\/posts\/19973\/revisions\/20207"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hvr-magnet.com\/fr\/wp-json\/wp\/v2\/media\/19974"}],"wp:attachment":[{"href":"https:\/\/hvr-magnet.com\/fr\/wp-json\/wp\/v2\/media?parent=19973"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hvr-magnet.com\/fr\/wp-json\/wp\/v2\/categories?post=19973"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hvr-magnet.com\/fr\/wp-json\/wp\/v2\/tags?post=19973"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}